Quickie Pulse Manuel de service Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 72
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
PULSE 6 SERVICE MANUAL
PAGE 7.6
SEPT 2011 SUNRISE MEDICAL
Motor Removal for chairs after S/N PLS-101919 and s/n prefix PLS6A &PLS6B
1. Remove 4 bolts from wheel and elevate
frame as shown. (Figure 7.6.1)
2. Using a 17mm socket and open end
wrench, remove front suspension bolt and nut
combination shown in (figure 7.6.2)
3. Remove motor from chair (figure 7.6.3)
4. Remove the 5 bolts from the motor plate
assembly with a 5mm Hex Key (figure 7.6.4)
Note: Upon re-assembly, make sure to re-tighten
the motor plate back to 40 inch/pounds of
torque.
5. Final motor removal step requires
disconnecting Motor connection from control
module and cutting the Ty-wrap (Figure 7.6.5).
Both parts should be re-attached when motor is
re-installed..
Section 7
fig. 7.6.1
fig. 7.6.2
fig. 7.6.3
fig. 7.6.4
fig. 7.6.5
Vue de la page 54